Common array manager - 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

 
Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.. Daily text for today 2023

From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a … The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp Jun 12, 2019 · This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of ... Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host.Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and …The Sun StorageTek Common Array Manager CLI Guide describes the commands in the sscsCLI. Consult the hardware installation guide for your array for information about the initial physical installation of an array. Related Documentation In addition, the Sun StorageTek Common Array Manager includes the following online documentation:Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …This document is designed to help clarify when a drive should be replaced, if this fault should be present on an array. Symptoms Include: SANtricity Storage Manager shows an alert for Impending Drive Failure Low Risk; Common Array Manager shows an alarm for Impending Drive Failure Risk Low (xx.66.1026)Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS)This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of …Dell OpenManage Array Manager, v.3.6.0.568.5, A05. Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests.Sun Storage 2530 Array - Version Not Applicable and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 6580 Array - Version All Versions and later All Platforms Goal. This document reviews the procedures for collecting performance statistics from arrays that can be managed using Sun Storage Common …The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and …The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.Storage Common Array Manager 6.8.1. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1 Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.10 (English) l Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Quick Start Guide (English) l This guide can help you with the basic steps of installing Oracle ... Sun Storage 2530 Array - Version Not Applicable and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 6580 Array - Version All Versions and later All Platforms Goal. This document reviews the procedures for collecting performance statistics from arrays that can be managed using Sun Storage Common … OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README document applies to Sun Storage ... Goal. This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. …Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM. Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide. Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) trapsCommon Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version … Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.10 (English) l Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Quick Start Guide (English) l This guide can help you with the basic steps of installing Oracle ... Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux Forums Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun StorageTek Common ... Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look …2 Sun StorageTek Common Array Manager Software 6.5.0 Release Notes • September 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM includes a distributed architecture which enables you to …2 Sun StorageTek Common Array Manager Software 6.5.0 Release Notes • September 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM includes a distributed architecture which enables you to …Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a … Sun StorageTek[TM] Common Array Manager (CAM)には、Sun StorEdge[TM]、Sun StorageTek [TM]、StorageTek[TM]、Sun Storage[TM]アレイのサポート・ベースの構成およびログを収集する機能があります。これはブラウザまたはCLIインタフェースを使用して実行できます。 The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays.Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software. From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Overview. Sun StorageTek (TM) Common Array Manager is a Shareware software in the category Desktop developed by Sun StorageTek (TM) Common Array Manager. The latest version of Sun StorageTek (TM) Common Array Manager is currently unknown. It was initially added to our database on 10/30/2007.From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options … OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README document applies to Sun Storage ... Jan 1, 2023 · Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated Learn Cycle has been run. Cause Using the Disk Array Manager The Disk Array Manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays Use this information to prepare disks for use in an array. Secure data deletion for Array Candidate pdisks that are formatted to RAID block sizeCategory filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …This document is designed to help clarify when a drive should be replaced, if this fault should be present on an array. Symptoms Include: SANtricity Storage Manager shows an alert for Impending Drive Failure Low Risk; Common Array Manager shows an alarm for Impending Drive Failure Risk Low (xx.66.1026) Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Common controller and disk array management tasks. You can perform various tasks to manage SAS RAID disk arrays. Use the information in this section to manage your RAID disk arrays. Using the Disk Array Manager The disk array manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays …Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. “Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Storage Common Array Manager 6.9.0. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a … Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host. Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. These release notes cover the software released on the Sun StorageTek Common Array Manager Software 6.0.0 CD. The Release Notes consist of the following sections: Features in This ReleaseLook for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages.Sun Storage Common Array Manager (CAM): How to Upgrade Firmware for Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays. (Doc …Now there's an easy way to manage your storage environment. Oracle's Sun Storage Common Array Manager software provides a common, simple-to-use interface for your Sun Storage arrays. The software takes the complexity out of storage management, enabling you to accelerate deployment, simplify your environment, and …Now there's an easy way to manage your storage environment. Oracle's Sun Storage Common Array Manager software provides a common, simple-to-use interface for your Sun Storage arrays. The software takes the complexity out of storage management, enabling you to accelerate deployment, simplify your environment, and …xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host …This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forThis article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of … Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp Performing Connection and Administration Tasks 36 Connection Tasks 37 Managing From the Site LAN 37 Managing an Array Isolated From the LAN 38 1 Sun StorageTek Array Administration Guide • March 2007 Installing the Remote CLI Client 38 About Host Bus Adapters 39 About Multipathing 39 General Administration Tasks 40 Accessing, Adding, …Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a …The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.

9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The …. Online radio

common array manager

Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. Now there's an easy way to manage your storage environment. Oracle's Sun Storage Common Array Manager software provides a common, simple-to-use interface for your Sun Storage arrays. The software takes the complexity out of storage management, enabling you to accelerate deployment, simplify your environment, and …The Sun StorageTek[TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge[TM], Sun StorageTek [TM], StorageTek[TM], Sun Storage[TM] Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information.The Sun StorageTek [TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge [TM], Sun StorageTek [TM], StorageTek …These Common Array Manager 6.0.1 Release Notes describe new features, known issues, patches and installation notes, and provide the most current product information. Sun StorageTek Common Array Manager Software Release Notes, Release 6.0.1 ...Dell OpenManage Array Manager, v.3.6.0.568.5, A05. Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI …This URL seems to be what you want: Installing the Typical Full Management Software. But having said that - you may want to look at a newer and more …Sun Storage Common Array Manager (CAM) - Version 6.10 to 6.10 [Release 6.0] Information in this document applies to any platform. Purpose. The purpose of this document is to provide an easily accessible reference for the supported browsers and operating systems for Sun Storage Common Array Manager (CAM), version 6.10.Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and …Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …Overview. Sun StorageTek (TM) Common Array Manager is a Shareware software in the category Desktop developed by Sun StorageTek (TM) Common Array Manager. The latest version of Sun StorageTek (TM) Common Array Manager is currently unknown. It was initially added to our database on 10/30/2007. Sun StorageTek Common Array Manager Installation Software CD 提供了三个与安装 有关的向导:. GUI (Graphical User Interface,图形用户界面)软件安装程序 - 使您可以通过图 形用户界面向导安装一系列选定的应用程序,以支持本地或远程的管理主机。. CLI (Command-Line Interface ... vi Sun StorageTek Common Array Manager User Guide for the J4000 Array Family • August 2008 The Event Life-Cycle 67 Setting Up Notification for Fault Management 68 Configuring Array Health Monitoring 76 To Configure the FMS Agent 76 To Enable Health Monitoring for an Array 78 Monitoring Alarms and Events 80Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed..

Popular Topics